Over charge detection voltage : 4.25V ± 25mV
Over charge release voltage : 4.10V ± 50mV
Over charge detection delay Time : 1.0s ± 0.3s
Cell-balance detection voltage : 4.20V ± 25mV
Cell-balance release voltage : 4.19V +25mV /-50mV
Cell-balance current : 40mA ± 4mA
Over discharge detection voltage : 2.5V ± 62.5mV
Over discharge release voltage : 3V ± 75mV
Over discharge detection delay Time : 119ms ± 36ms
Charging overcurrent detection current : 20A ± 12A
Charging overcurrent detection delay Time : 8ms ± 3ms
Discharge overcurrent detection current : 40A ± 8A
Discharge overcurrent detection delay Time : 9.9ms ± 3ms
Overtemperature detection temperature : 70°C ± 5 °C
Overtemperature release temperature : 60 °C +5 / -10°C
Consumption current (Operating mode) : Max u30A

Over charge detection voltage : 4.25V ± 25mV
Over charge release voltage : 4.10V ± 50mV
Over charge detection delay Time : 1.0s ± 0.3s
Cell-balance detection voltage : 4.20V ± 25mV
Cell-balance release voltage : 4.19V +25mV /-50mV
Cell-balance current : 40mA ± 4mA
Over discharge detection voltage : 2.5V ± 62.5mV
Over discharge release voltage : 3V ± 75mV
Over discharge detection delay Time : 119ms ± 36ms
Charging overcurrent detection current : 20A ± 12A
Charging overcurrent detection delay Time : 8ms ± 3ms
Discharge overcurrent detection current : 40A ± 8A
Discharge overcurrent detection delay Time : 9.9ms ± 3ms
Overtemperature detection temperature : 70°C ± 5 °C
Overtemperature release temperature : 60 °C +5 / -10°C
Consumption current (Operating mode) : Max u30A